Starting Procedure of Alfa Laval Aalborg Av 6N EGB, ensure drain valves are shut, open the air vent, ensure circulating pump valves are open, crack open the inlet valve and close air vents when steam or water starts to issue, slowly open the inlet/outlet valve, and check valves and flanges before allowing the unit to warm through. The starting procedure of the Alfa Laval Aalborg Av 6N Exhaust Gas Boiler is an essential step for ensuring its efficient operation.

Starting Procedure of Alfa Laval Aalborg Av 6N EGB

Familiarity with Boiler Control Screen and Valve Positions

https://yasirarafin.com/alfa-leval-av-6n/

Starting the Engine and Charging the Boiler

Cold Start Procedure for Low Water Temperature

Starting Procedure Of Alfa Laval Aalborg Av 6N EGB

Operating Modes: Auto vs. Manual

Auto Operation

Manual Operation Mode Settings

Checking Steam Drum Water Level

Pressure Control by Damper

Step 1: Damper Opening Command and Temperature Control

Open the damper manually to 25% and Wait until temperature inside steam drum become 120⁰C. After reaching 120⁰C close the steam drum venting valve

Step 2: Damper Opening at 2 Bar Pressure

Open the damper manually to 50% once the steam pressure reaches 2 bar.

Step 3: Damper Opening at 4 Bar Pressure

Open the damper manually to 100% once the steam pressure reaches 4 bar.

Blow Out Valve Operation

Water Level Control During Blow Out

Superheated Steam Temperature Control

Considerations for Steam Turbine Operation

Important Guidelines and Considerations

Pressure Settings and Steam Turbine Operation

Explanation of the recommended pressure settings and considerations for steam turbine operation.

HP Pump and LP Pump Delivery Pressure

Feed Water Tank Temperature Maintenance

Soot Blowing Procedure

Frequency and Conditions for Soot Blowing

Interlocks for Soot Blower Activation

  1. The necessary boiler’s steam delivery pressure must be greater than 7 bar.
  2. The damper should be open by at least 25%.
  3. The soot blower’s limit switch needs to be in the operating position (the green WOIS indication needs to be on in the soot blower page).

Initiating Soot Blow Command

Instructions for initiating the soot blow command from the Human-Machine Interface (HMI).

Troubleshooting And Maintenance Tips

In order to ensure the smooth starting procedure of the Alfa Laval Aalborg Av 6N Exhaust Gas Boiler, it is important to be aware of the common issues that may arise during the starting process. By understanding these issues and implementing proper troubleshooting techniques and regular maintenance practices, you can ensure that your boiler operates efficiently and effectively.

Common issues faced during the starting procedure

During the starting procedure, there are several common issues that may be encountered. These include:

Identifying and addressing these issues promptly is essential to ensure the successful starting of the Alfa Laval Aalborg Av 6N Exhaust Gas Boiler.

FAQ’S

How Do You Start A Boiler?

To start an boiler, hear some basic steps:

  1. Close drain valves and open air vent.
  2. Ensure circulating pump valves are open.
  3. Crack open the inlet valve and close air vents when steam or water starts to come out.
  4. Slowly open the inlet and outlet valves.
  5. Check valves and flanges.
  6. Allow the unit to warm through. It is important to follow these steps for a successful start-up of the exhaust gas boiler.

What Is The Operation Of Exhaust Gas Boiler?

Exhaust gas boilers operate by utilizing the heated exhaust gas from engines as a source of energy to generate steam or thermal oil. They are designed with a cylindrical shell, smoke tubes, and a water drum, with stay tubes providing support.

Opening drain valves, air vents, and inlet/outlet valves while ensuring pump valves are open allows for proper operation.

What Is The Difference Between Auxiliary Boiler And Exhaust Gas Boiler?

The difference between auxiliary boiler and exhaust gas boiler is the source of energy used. The exhaust gas boiler uses the heated exhaust gas from engines, while the auxiliary boiler can be fired with oil or gas. They also differ in the number of valves required for operation.

What Is An Exhaust Gas Boiler And How It Is Constructed And Work?

An exhaust gas boiler is a vertical boiler with a cylindrical shell surrounding the boiler tubes and water drum. It works by using the heated exhaust gas from engines as a source of energy to generate steam or thermal oil.

The boiler is constructed with smoke tubes and stay tubes for support.