Squirrel cage induction motors are very common. They are used in many machines. They are simple and strong. But they need help to start. Let’s learn how.
Why Do Motors Need Help to Start?
Starting a motor needs a lot of power. This power can damage the motor. It can also cause problems in the electric system. So, we use special methods to start motors.
Direct On Line (DOL) Starter
The DOL starter is the simplest method. It connects the motor directly to the power supply. The motor gets full voltage. This method is simple and cheap.
Advantages:
- Easy to use
- Low cost
- Simple design
Disadvantages:
- High starting current
- Can damage motor
- Can cause voltage drop
Star-Delta Starter
The star-delta starter is more complex. It uses two stages to start the motor. First, the motor is connected in star. Then, it is switched to delta. This reduces the starting current.
Advantages:
- Reduced starting current
- Less voltage drop
- Good for larger motors
Disadvantages:
- More complex design
- Higher cost
- Needs more space
Autotransformer Starter
The autotransformer starter uses a special transformer. It reduces the voltage before it reaches the motor. This reduces the starting current.
Advantages:
- Reduced starting current
- Smooth start
- Good for high power motors
Disadvantages:
- More expensive
- Complex design
- Needs maintenance
Soft Starter
The soft starter uses electronics. It controls the voltage to the motor. It slowly increases the voltage. This gives a smooth start.
Advantages:
- Very smooth start
- Reduces wear and tear
- Good for sensitive machines
Disadvantages:
- Expensive
- Complex design
- Needs electronic skills
Variable Frequency Drive (VFD)
The VFD is the most advanced method. It controls the frequency of the power supply. It can control the speed of the motor. It gives a very smooth start.
Advantages:
- Very smooth start
- Controls motor speed
- Reduces energy use
Disadvantages:
- Very expensive
- Complex design
- Needs advanced skills
Comparison Table
Method | Advantages | Disadvantages |
---|---|---|
DOL Starter | Easy to use, Low cost | High starting current, Can damage motor |
Star-Delta Starter | Reduced starting current, Less voltage drop | More complex, Higher cost |
Autotransformer Starter | Reduced starting current, Smooth start | More expensive, Complex design |
Soft Starter | Very smooth start, Reduces wear | Expensive, Complex design |
VFD | Very smooth start, Controls speed | Very expensive, Complex design |

Credit: favreadblogs.blogspot.com
Choosing the Right Method
Choosing the right method depends on many factors. You must consider the size of the motor. Also, think about the cost. The complexity of the system is also important.

Credit: www.slideshare.net
Frequently Asked Questions
What Are The Starting Methods For Squirrel Cage Induction Motors?
The common starting methods are Direct-On-Line (DOL), Star-Delta, and Autotransformer starting.
Why Use Direct-on-line (dol) Starting?
DOL is simple and cost-effective. It directly connects the motor to the power supply.
How Does Star-delta Starting Work?
Star-Delta reduces starting current. It initially connects in star, then switches to delta.
What Is The Autotransformer Starting Method?
Autotransformer starting uses a transformer to reduce voltage during startup, then switches to full voltage.
Conclusion
Squirrel cage induction motors need help to start. There are many methods to choose from. Each method has its own advantages and disadvantages. Choose the right one for your needs.